ILD 300
Types
Loop driver up to 400m2Producer
Ampetronic Ltd., Unit 2, Trentside Business Village, Farndon Road, Newark, United KingdomBrief description
Perimeter installation suitable for Theatres, Sport halls, Education enviroments, places of worship, lecture HallsRecommended area covered by this driver
400m2Accesories
compatible connectorsOwn experiences, UNB experts, Equalizent experts, Racio experts
very good listening (stereo) with hearing aids TExperiences of UNB clients, Equalizent clients, Racio clients
Institution should invest to this amplifier amost everywhere, they can profit from increased attendance or can benefit from new custumerMore informations
unb@cmjn.cz,https://www.ampetronic.co
Supplier for the Czech Republic, Austria and Slovenia
Unie neslyšících Brno sociální podnik s.r.o., Palackého třída, 114, Brno tel:541245321,mob:725605216, email: polacek@pomuckyproneslysici.czComparing with other similar products
This equipment is favourite at middle size theathre - up to cca 50 people
Meeting room
Seminar room
Private homes
Receptions and waiting rooms
Other
Seminar room
Private homes
Receptions and waiting rooms
Other
INPUTS | ||||||||
Power | 35W 230V AC nominal, 45-65 Hz , Power switch and LED indicator on front panel | |||||||
Microphone | Programmable between microphone and line via panel menu | |||||||
Microphone / Microphone specification; 200 - 600Ω, sensitivity -64dBu. | ||||||||
Line Selectable 12V phantom power on microphone only | ||||||||
Line sensitivity; -39dBu | ||||||||
Input 2 can also be used for AES3 Digital Audio Signals | ||||||||
Slave In | 6.35mm jack socket for linking more than one amplifier. | |||||||
Inserting plug disables other inputs | ||||||||
OUTPUTS | ||||||||
Loop Output Drive Voltage | 33.9VRMS (48Vpk) at maximum output current per channel | |||||||
Loop Output/Drive Current | D10-X | |||||||
• 10ARMS (14.1Apk) up to 60 seconds continuous 1kHz sine wave, peak >14.1A per channel | ||||||||
• Cont. pink noise 4.7ARMS short term peaks >14.1A per ch. | ||||||||
Slave Out | 6.35mm jack socket to connect to other slave amplifiers | |||||||
Loop Connectors | Neutrik NL2 Speakons (supplied) for each output | |||||||
Loop Monitor | Provides access to monitor actual loop current via a 3.5mm stereo headphone connector on front panel, Channel A on left, channel B on right. | |||||||
DC Output | Resettable, fuse protected 12V 0.1A. Operation can be configured via menu | |||||||
AUDIO SYSTEM | ||||||||
Frequency Response | 80Hz to 6.5kHz | |||||||
Distortion | THD+N <0.2% 1kHz sine at full current | |||||||
Automatic Gain Control | The AGC is optimised for speech. Dynamic range >36dB | |||||||
Metal Loss Correction | Corrects system frequency response due to metal structures in a building. Frequency to be set via the menu.Gain constant at 1kHz, adjustable gain slope from 0 to 4dB per octave in 0.25dB increments. Custom 2 slope MLC allows different slopes and transition | |||||||
Phase Shift | User selectable at 0° or 90° between outputs |